72 research outputs found

    Catalytic dechlorination of diclofenac by biogenic palladium in a microbial electrolysis cell

    Get PDF
    Diclofenac is one of the most commonly detected pharmaceuticals in wastewater treatment plant (WWTP) effluents and the receiving water bodies. In this study, biogenic Pd nanoparticles (bio-Pd) were successfully applied in a microbial electrolysis cell (MEC) for the catalytic reduction of diclofenac. Hydrogen gas was produced in the cathodic compartment, and consumed as a hydrogen donor by the bio-Pd on the graphite electrodes. In this way, complete dechlorination of 1 mg diclofenac l-1 was achieved during batch recirculation experiments, whereas no significant removal was observed in the absence of the biocatalyst. The complete dechlorination of diclofenac was demonstrated by the concomitant production of 2-anilinophenylacetate (APA). Through the addition of -0.8 V to the circuit, continuous and complete removal of diclofenac was achieved in synthetic medium at a minimal HRT of 2 h. Continuous treatment of hospital WWTP effluent containing 1.28 mu g diclofenac l-1 resulted in a lower removal efficiency of 57%, which can probably be attributed to the affinity of other environmental constituents for the bio-Pd catalyst. Nevertheless, reductive catalysis coupled to sustainable hydrogen production in a MEC offers potential to lower the release of micropollutants from point-sources such as hospital WWTPs

    Bio-palladium : from metal recovery to catalytic applications

    Get PDF
    While precious metals are available to a very limited extent, there is an increasing demand to use them as catalyst. This is also true for palladium (Pd) catalysts and their sustainable recycling and production are required. Since Pd catalysts exist nowadays mostly under the form of nanoparticles, these particles need to be produced in an environment-friendly way. Biological synthesis of Pd nanoparticles (bio-Pd) is an innovative method for both metal recovery and nanocatalyst synthesis. This review will discuss the different bio-Pd precipitating microorganisms, the applications of the catalyst (both for environmental purposes and in organic chemistry) and the state of the art of the reactors based on the bio-Pd concept. In addition, some main challenges are discussed, which need to be overcome in order to create a sustainable nanocatalyst. Finally, some outlooks for bio-Pd in environmental technology are presented

    Online flow cytometric monitoring of microbial water quality in a full-scale water treatment plant

    Get PDF
    The ever-increasing need for high-quality drinking and process waters, and growing public awareness about possible contamination, drive efforts for the further development of automated control of water treatment plants. For example, membrane filtration processes and reverse osmosis in particular are generally regarded as a safe barrier for inorganic, organic, and microbial contamination. Yet, to ensure the final water quality and to increase the confidence of the end-user, intensive and preferably online monitoring should be further implemented as an early-warning tool to control membrane integrity and to prevent microbial regrowth in the distributing network. In this paper, we test the applicability of flow cytometry and cytometric fingerprinting for a full-scale water treatment plant. We demonstrate in a full-scale water treatment plant that flow cytometry can be used as online monitoring tool and that changes in water quality can be observed, which are not monitored by commonly used online quality parameters. Furthermore, we illustrate with ultrafiltration that process conditions impact the flow cytometric cell counts

    Safeguarding the microbial water quality from source to tap

    Get PDF
    Anthropogenic activities and climate change can deteriorate the freshwater quality and stress its availability. This stress can, in turn, have an impact on the biostability of drinking water. Up to now, the microbiological quality of drinking water has been maintained through the selection of high-quality water sources allied to the use of disinfectants and the removal of organic carbon. But as freshwater becomes richer in other nutrients, strategies used so far may not suffice to keep a steady and high-quality supply of drinking water in the future. This article readdresses the discussion on drinking water biostability. We need to reframe the concept as a dynamic equilibrium that considers the available nutrients and energy sources (potential for growth) relative to the abundance and composition of the bacterial community (potential to consume the available resources)

    Flow cytometric fingerprinting to assess the microbial community response to changing water quality and additives

    Get PDF
    Water is used for a very broad range of industrial applications with different water quality requirements. In all cases, the microbial water quality remains of importance as the microbial community can cause biofouling, microbial induced corrosion, odor problems, or health hazards. A close and accurate monitoring of the microbial water quality is therefore relevant for all water types used in industrial applications. Flow cytometry and additionally flow cytometric fingerprinting have been proposed before as methods to monitor the aquatic microbial communities but it remains unclear on how sensitive the fingerprinting method is for detecting quality changes in practice for different types of water. In this paper, we compared the microbial dynamics of coarsely filtered surface water, tap water, and demineralized water by challenging these waters with different concentrations and types of nutrients (C, N, and P) and additives such as corrosion inhibitors and biocides. We demonstrated that the cytometric fingerprints of the aquatic microbial communities differed in function of the type and concentration of product added, but that these differences are dependent on the type of water. Flow cytometry proved to be sensitive enough to detect subtle changes in microbial communities and to measure bacterial regrowth in different types of water. As a result, we conclude that cytometric fingerprints can be considered as indirect indicators of the physical-chemical composition of the water and a tool to monitor water biostability, as a tell-tale for minor environmental changes

    Biogenic palladium enhances diatrizoate removal from hospital wastewater in a microbial electrolysis cell

    Get PDF
    decrease the load of pharmaceuticals to the environment, decentralized wastewater treatment has been proposed for important point-sources such as hospitals. In this study, a microbial electrolysis cell (MEC) was used for the dehalogenation of the iodinated X-ray contrast medium diatrizoate. The presence of biogenic palladium nanoparticles (bio-Pd) in the cathode significantly enhanced diatrizoate removal by direct electrochemical reduction and by reductive catalysis using the H(2) gas produced at the cathode of the MEC. Complete deiodination of 3.3 mu M (2 mg L(-1)) diatrizoate from a synthetic medium was achieved after 24 h of recirculation at an applied voltage of -0.4 V. An equimolar amount of the deiodinated metabolite 3,5-diacetamidobenzoate (DAB) was detected. Higher cell voltages increased the dehalogenation rates, resulting in a complete removal after 2 h at -0.8 V. At this cell Voltage, the MEC was also able to remove 85% of diatrizoate from hospital effluent containing 0.5 mu M (292 mu g L(-1)), after 24 h of recirculation. Complete removal was obtained when the effluent was continuously fed at a volumetric loading rate of 204 mg diatrizoate m(-3) total cathodic compartment (TCC) day(-1) to the MEC with a hydraulic retention time of 8 h. At -0.8 V, the MEC system could also eliminate 54% of diatrizoate from spiked urine during a 24 h recirculation experiment. The final product DAB was demonstrated to be removable by nitrifying biomass, which suggests that the combination of a MEC and bio-Pd in its cathode offers potential to dehalogenate pharmaceuticals, and to significantly lower the environmental burden of hospital waste streams
    corecore